Contact Us
Armored Cable

Duplex Armored Cable

    Duplex Armored Cable
    Duplex Armored Cable
Duplex Armored Cable

Duplex Armored Cable

Indoor Flexible Armor


GJSFJBH GJSFJBV indoor figure-8 duplex flexible armored blue LSZH flame retardant TPU jacket cable


Cable Mechanical Characteristics

Fiber Count Tight Buffer Cable OD (mm) Cable G.W. (kg/km) Tensile Resistance
(N)
Long/Short Term
Crush Resistance(N/100mm)
Long/Short Term
Bending Radius
(mm)
Static/Dynamic
2 0.6 2.0*4.0 30 300/750 200/1000 20D/10D
2 0.9 3.0*6.0 43 300/750 200/1000 20D/10D

Environment Performance

Operation Temperature (°C) -20 ~ +60
Storage Temperature (°C) -20 ~ +60

Fiber Parameter

Single Mode Fiber
  Unit G.652D G657A1 G657A2
Cladding Diameter μm 125±1.0 125±0.7 125±0.7
Cladding non-circularity % ≤ 1.0 ≤ 0.7 ≤ 0.7
Core-cladding Concentricity Error μm ≤ 0.6 ≤ 0.5 ≤ 0.5
Coating Diameter μm 245±7 245±5 245±5
Coating non-circularity % ≤ 6.0 ≤ 6.0 ≤ 6.0
Cladding-coating concentricity error μm ≤ 12.0 ≤ 12.0 ≤ 12.0
Cable Cutoff Wavelength (λcc) nm ≤ 1260 ≤ 1260 ≤ 1260
Mode Field Diameter 1310nm μm ≤ 0.4 ≤ 0.4 ≤ 0.4
1550nm μm ≤ 0.3 ≤ 0.3 ≤ 0.3
Multimode Fiber
  Unit 62.5/125 50/125 OM3 OM4
Core Diameter μm 62.5±2.5 50±2.5 50±2.5 50±2.5
Cladding Diameter μm 125±1.0 125±1.0 125±1.0 125±1.0
Core Non-circularity % ≤ 5.0 ≤ 5.0 ≤ 5.0 ≤ 5.0
Cladding Non-circularity % ≤ 1.0 ≤ 1.0 ≤ 1.0 ≤ 1.0
Core-cladding Concentricity Error μm ≤ 1.5 ≤ 1.5 ≤ 1.0 ≤ 1.0
Coating Diameter μm 245±7 245±7 245±7 245±7
Coating Non-circularity % ≤ 6.0 ≤ 6.0 ≤ 6.0 ≤ 6.0
Cladding-coating Concentricity Error μm ≤ 12.0 ≤ 12.0 ≤ 12.0 ≤ 12.0
OFL Bandwidth 850nm MHz·km ≥ 160 ≥ 500 ≥ 1500 ≥ 3500
1300nm MHz·km ≥ 500 ≥ 500 ≥ 500 ≥ 500
TAGS »
Product Inquiry
Email us if you are interested in ts communication fiber optic products and solutions.